Skip to content

Monitoring Items Reference

Item Occurence Remarks
TS_Sync_loss
  • TS is not in sync
ETR290 1.1
Sync_byte_error
  • Synchronous byte is not “0x47”
ETR290 1.2
PAT_error
  • PID=0x0000 is not detected every 0.5 seconds.
  • PID=0x0000 does not contain PAT.
  • The transport_scrambling_control of TS packet with PID=0x0000 is not ‘00’
ETR290 1.3
Continuity_count_error
  • continuity_counter is not continued
ETR290 1.4
PMT_error
  • PID of PMT (table_id=0x02) specified by PAT is not detected every 0.5 seconds.
  • transport_scrambling_control of PID containing table_id=0x02 is not ‘0’
ETR290 1.5
Transport_error
  • transport_error_indicator is ‘1’
ETR290 2.1
CRC_error
  • CRC value is different
ETR290 2.2
PCR_error
  • PCR discontinuity of 100ms or more occur without specific instructions.
  • The interval of two consecutive PCR is 100ms or more.
ETR290 2.3
PCR_accuracy_error
  • PCR accuracy is not within ± 500ns.
ETR290 2.4
PTS_error
  • PTS cycle is 700ms or more
ETR290 2.5
CAT_error
  • Contents of the section is CAT, when transport_scrambling_control is not ’00’
  • Table_id other than 0x01 is found at PID=0x0001.
ETR290 2.6